*                        HELP FOR DALLAS DEVICES                            *
*                          (informal document)                              *
*                                                                           *
*****************************************************************************


****************************************************************************

DS1624: (Digital Thermometer and Serial EEPROM)
----------------------------------------------

To program the configuration byte feature you must set the Special Data #1
flag to Y in TaskLink or the "Program Configuration" flag to Y in Terminal
mode.

CONFIGURATION/STATUS REGISTER:
Unisystem RAM mapping:
----------------------
       0x0100           Bit0     1SHOT (One Shot Mode)

If 1SHOT is 1  the DS1624 will perform one temperature conversion upon
                 receipt of the Start Convert T protocol.