Solutions Database
Quicksim II: Unable to resolve expression symbol lca_technology, NULL model will be inserted
Record #141
Product Family: Software
Product Line: Mentor
Problem Title:
Quicksim II: Unable to resolve expression symbol lca_technology, NULL
model will be inserted
Problem Description:
In Mentor 8, an error similar to the following may appear when invoking
Quicksim:
// Error: Unable to resolve expression symbol lca_technology (from:
DDMS/EDDM/EDDM General 41)
// Error: Instance: '/BLANK1'
// Trouble accessing MODEL property on primitive instance.
// May be bad property evaluation. NULL model will be inserted.
(from: Analysis/Digital Simulation Utilities/Dsim 16)
// Error: Unable to resolve expression symbol lca_technology (from:
DDMS/EDDM/EDDM General 41)
// Error: Instance: '/BLANK2'
// Trouble accessing MODEL property on primitive instance.
// May be bad property evaluation. NULL model will be inserted.
(from: Analysis/Digital Simulation Utilities/Dsim 16)
// Error: Unable to resolve expression symbol lca_technology (from:
DDMS/EDDM/EDDM General 41)
// Error: Instance: '/BLANK3/UNKNOWN1'
// Trouble accessing MODEL property on primitive instance.
// May be bad property evaluation. NULL model will be inserted.
(from: Analysis/Digital Simulation Utilities/Dsim 16)
Solution 1:
This is caused by a non-existent or incorrectly written simulation
viewpoint for the design. The solution is to run PLD_DVE_Sim on the
design, specifying the correct part family, from either PLD Design Manager
or the command line. An XC4000 design, for example, would use:
pld_dve_sim blanking_design xc4000
If a default viewpoint already exists, you will need to FIRST delete that
viewpoint before you can run PLD_DVE_Sim. See Solution 766, "How to delete
a design viewpoint in Mentor 8."
Note: If Timsim8 -o was used to create the simulation model, be sure to run
Timsim8 instead of PLD_DVE_Sim. This is because Timsim8 -o links timing
information into the viewpoint after it runs PLD_DVE_Sim.
End of Record #141