This file is not included in the patch!! See readme.txt instead. (joey-11/1/96).

Please note that the dates listed in each file description refers to the 
date that the file was added to the patch, not the file creation date.

-------------------------------------------------------------------------------
File Name:         FITTERPC.ZIP (PC), FITTERSN.TAR (Sun), FITTERHP.TAR (HP)
Last Updated:      12/09/96
Affected Products: XACT-CPLD  v6.01 and earlier
                   XABEL-CPLD v6.11, v6.10
   		   Foundation v6.01

*******************************************************************************
************ Be sure to download and install the EZTag patch also *************
*******************************************************************************

MODEL6.CHP     8/08/96  XACT-CPLD 6.01 - Correction to XC95216HQ208 and
                                  6.00   XC95180HQ208 package model. 
                       XABEL-CPLD 6.10   Pins 66 and 69 are GND, not I/O.
                                  6.11
                       Foundation 6.01
              10/09/96  XACT-CPLD 6.01 - Correction to XC9572 package models.
                                  6.00   Pad 19 dropped because of REMAP scheme. 
                       XABEL-CPLD 6.10   
                                  6.11
                       Foundation 6.01
              03/04/97 all             - disable 95288 for a while 
MODELF.TIM     8/08/96 XACT-CPLD  6.01 - Adjusted product term clock timing for
                                  6.00   XC95108 -7, -10 and -15. The new
		      XABEL-CPLD  6.10	 timing is:
                                  6.11               -7    -10   -15
                      Foundation  6.01   tPSU (min)  1.5    2.5   4.0
                                         tPH  (min)  4.0    4.0   4.0
                                         tPCO (min)  9.5   10.5  12.0

                                         The value of tPTCK in the timing model
					 is now:
                                                     -7     -10    -15
                                         tPTCK (max) 4.0    3.5    2.5

                                         Yes, tPTCK is faster in the timing
                                         model for slower speed bins. 					 

HPLUSAS6.EXE  9/10/96  XACT-CPLD  6.01 - Corrects internal software error 
                                  6.00   occuring when a negative polarity 
	               XABEL-CPLD 6.10   WIRE-AND equation in FastCONNECT
                                  6.11   drives another WIREAND equation.
		       Foundation 6.01   For example:
                                           /a = b * /c; FC node 
                                            d = /a * e; FC node

HITOP.EXE     9/10/96  XACT-CPLD  6.01 - Eliminates core dump during 
                                  6.00   product term assignment optimization 
	               XABEL-CPLD 6.10   
                                  6.11 - Eliminates core dump when  
		       Foundation 6.01   customer trys to mistakenly   
                                         drive two output pins from   
                                         same logic source. (A logic 
                                         function can only drive one
                                         output pin.)
                                       
                                       - Eliminates incorrect inversion
                                         of signals that used local feed
                                         back path.

                                       - Refined product term assignment 
                                         optimization for fitting 
                                         efficiency
              02/13/97 all             - Correct 95288 imux bitmaps & foe
              03/3/97  all             - Error if signals assigned to same pin
              03/25/97 all             - Node tristates created if buffering occured
TSIM.EXE      9/10/96  XACT-CPLD  6.01 - Rebuilt for consistency
                                  6.00   on the HP platform
		       XABEL-CPLD 6.10
				  6.11
                       Foundation 6.01
              03/04/97 all             - Duplicate tristate symbols if exporting
FSIM.EXE      9/10/96  XACT-CPLD  6.01 - Rebuilt for consistency
                                  6.00   on the HP platform
		       XABEL-CPLD 6.10
				  6.11 
                       Foundation 6.01 
                                      

                      Affected
Contents      Date    Products	  Ver    Description		   		   
TAENGINE.EXE  7/31/96 XACT-CPLD   6.00 - Corrects incorrect reporting of set-up
                      XABEL-CPLD  6.10   time of a clock signal to itself.
                                         Tracing of this false path makes
                                         performance appear to be slower than
                                         it really is.

              9/10/96  XACT-CPLD  6.01 - Rebuilt for consistency across PC,
                                  6.00   HP and SUN platforms. This file
		       XABEL-CPLD 6.10   was originally contained in TAPC
				  6.11   and TASUN patches 
                       Foundation 6.01     

HPREP6.EXE   10/31/96  XACT-CPLD  6.01 - Supports 9572 JEDEC programming
                                  6.00   for -7/-10/-15 speed grades and 
	               XABEL-CPLD 6.10   PC84/PQ100/TQ100 packages.
                                  6.11 - Supports EZTAG download. 
	     12/06/96  XACT-CPLD  6.01 - Fix protection fault if TMV test
		                  6.00   vectors + TQ100 package is used
		       XABEL-CPLD 6.10
		                  6.11
		       Foundation 6.01
	     03/25/97  all             - Enable 95288

******************************************************************************
*                         Install Instructions                               *
*									     *
* Unzip (Untar) files and copy into fitter as follows:                       *
*                                                                            *
* For XACT-CPLD                                                              *
*     For pc  : c:\xact9000\data\model6.chp                                  *
*               c:\xact9000\data\modelf.tim				     *
*		c:\xact9000\hplusas6.exe				     *
*		c:\xact9000\hitop.exe				 	     *
*		c:\xact9000\taengine.exe				     *
*		c:\xact9000\hprep6.exe					     *
*     For sun : <xact9000>/data/model6.chp		     	             *
*               <xact9000>/data/modelf.tim				     *
*		<xact9000>/bin/sparc/hplusas6				     *
*		<xact9000>/bin/sparc/hitop				     *
*		<xact9000>/bin/sparc/taengine				     *
*		<xact9000>/bin/sparc/hprep6				     *
*     For hp  : <xact9000>/data/model6.chp				     *
*               <xact9000>/data/modelf.tim                                   *
*		<xact9000>/bin/hppa/hplusas6				     *
*		<xact9000>/bin/hppa/hitop				     *
*		<xact9000>/bin/hppa/tsim				     *
*		<xact9000>/bin/hppa/fsim				     *
*		<xact9000>/bin/hppa/taengine				     *
*		<xact9000>/bin/hppa/hprep6				     *
*									     *
* For Foundation							     *
*             	c:\xact9000\data\model6.chp				     *
*               c:\xact9000\data\modelf.tim				     *
*		c:\xact9000\hplusas6.exe				     *
*		c:\xact9000\hitop.exe				 	     *
*		c:\xact9000\taengine.exe				     *
*		c:\xact9000\hprep6.exe    				     *
*								             *
* For XABEL-CPLD 		                                             *
*               c:\xabel6\xact9k\data\model6.chp			     *
*	        c:\xabel6\xact9k\data\modelf.tim                             *
*		c:\xabel6\xact9k\hplusas6.exe				     *
*		c:\xabel6\xact9k\hitop.exe				     *
*		c:\xabel6\xact9k\taengine.exe (XC9K fitter)    		     *
*		c:\xabel6\xact\taengine.exe   (XC7K fitter)    		     *
*		c:\xabel6\xact9k\hprep6.exe               		     *
******************************************************************************